Can a triple wall flue pipe be used for a wood stove.
Triple wall flue pipe clearance.
Duraplus chimney systems lock tightly with twist lock precision and require a 2 clearance to combustible materials.
This boosts stove efficiency by exhausting hot flue gases easily and efficiently.
Our class a tiple wall chimney systems stay cool on the outside while providing a hot draft on the inside.
Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall.
A straight up double wall flue pipe assembly.
Previous next consistently the first to market with new innovations in venting systems duravent has captured a leadership position in emerging markets.
This one is the sealed type.
Dvl s double wall air insulated design reduces clearances to combustibles from 18 in.
The minimum installation clearances for certified double wall flue pipes are much less than those for single wall pipes.
Dvl improves stove performance by maintaining high flue gas temperatures for a strong steady draft.
All stove chimney pipe is chosen and classified by the inside diameter.
There are two general types of.
We prioritize maintaining highest quality products and providing excellent service to our end customers and our distributors.
Many think stovepipe can run from the wood stove right up through the ceiling and roof.
For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls.
Once these clearances are met you must convert your stove pipe to class a chimney pipe for proper venting of your stove.
For safety the single or double wall black stovepipe.
To 6 in the closest clearance to a wall of any connector pipe.
Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Learn more about our company our products duravent offers over twenty different product lines for residential.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe.
If your flue has a 6 inside diameter you will choose from the 6 stove and chimney pipe categories.
9 is a typical clearance between a gas fired boiler or furnace flue connector and combustibles.
See fire clearances single wall metal flues vents for the clearance from combustibles required for flue vent connectors these are not chimneys but rather the flue pipe smoke pipe or stack pipe that connects a heating appliance to a chimney.
Metal flue fire clearance requirements single wall metal pipe flues gas fired equipment.
Fire clearances required range from 6 to 36 depending on the equipment.